Peer-reviewed veterinary case report
Analytical validation of commercially available methods for acute phase proteins quantification in pigs.
- Journal:
- Research in veterinary science
- Year:
- 2007
- Authors:
- Tecles, F et al.
- Affiliation:
- Animal Medicine and Surgery Department · Spain
Abstract
The aim of this study was to validate commercially available methods for porcine haptoglobin (Hp), C-reactive protein (CRP), serum amyloid A (SAA) and major acute phase protein (Pig-MAP) determinations. Intra and inter assay coefficients of variation (CVs) were lower than 20% in all cases with exception of inter assay CVs for CRP and Pig-MAP assays with samples of low acute phase proteins concentration, and for SAA assay at any acute phase proteins concentration. All methods showed good linearity and detection limits were low enough to detect APPs levels in healthy animals. Hp and SAA were very affected by haemolysis. Lipaemia influenced mainly on SAA determination. Over 15-fold increase was observed in CRP and SAA concentrations after artificially induced inflammation by a single subcutaneous dose of turpentine, whereas Hp and Pig-MAP increased less than 5-fold.
Find similar cases for your pet
PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.
Search related cases →Original publication: https://pubmed.ncbi.nlm.nih.gov/17141287/