Peer-reviewed veterinary case report
Automatic spine curvature estimation from X-ray images of a mouse model.
- Journal:
- Computer methods and programs in biomedicine
- Year:
- 2017
- Authors:
- Okashi, Omar Al et al.
- Affiliation:
- Department of Applied Computing · United Kingdom
- Species:
- rodent
Abstract
Automatic segmentation and quantification of skeletal structures has a variety of applications for biological research. Although solutions for good quality X-ray images of human skeletal structures are in existence in recent years, automatic solutions working on poor quality X-ray images of mice are rare. This paper proposes a fully automatic solution for spine segmentation and curvature quantification from X-ray images of mice. The proposed solution consists of three stages, namely preparation of the region of interest, spine segmentation, and spine curvature quantification, aiming to overcome technical difficulties in processing the X-ray images. We examined six different automatic measurements for quantifying the spine curvature through tests on a sample data set of 100 images. The experimental results show that some of the automatic measures are very close to and consistent with the best manual measurement results by annotators. The test results also demonstrate the effectiveness of the curvature quantification produced by the proposed solution in distinguishing abnormally shaped spines from the normal ones with accuracy up to 98.6%.
Find similar cases for your pet
PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.
Search related cases →Original publication: https://pubmed.ncbi.nlm.nih.gov/28254073/