PetCaseFinder

Peer-reviewed veterinary case report

Development of an antibody-detection ELISA for Fasciola hepatica and its evaluation against a commercially available test.

Journal:
Research in veterinary science
Year:
2005
Authors:
Salimi-Bejestani, M R et al.
Affiliation:
Liverpool School of Tropical Medicine/Faculty of Veterinary Science · United Kingdom

Abstract

An ELISA was developed for the detection of Fasciola hepatica antibody in serum of cattle. The assay was applied to sera from 258 naturally infected cattle, 256 non-infected cattle and six calves experimentally infected with F. hepatica. The diagnostic sensitivity and specificity of the ELISA test was 98% (95% confidence intervals, 96-100%) and 96% (95% confidence intervals, 93-98%) respectively at a cut-off value of 15% positivity. The results using sera from the experimentally infected calves showed that antibodies were first detected 2-4 weeks after infection. The ELISA test was also compared to the commercially available Bio-X bovine F. hepatica ELISA kit. A subset of 39 positive sera and 47 negative sera were selected from the samples used to evaluate the in-house test. The results indicated that the agreement between the two tests was almost perfect (k statistic=0.82).

Find similar cases for your pet

PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.

Search related cases →

Original publication: https://pubmed.ncbi.nlm.nih.gov/15563926/