PetCaseFinder

Peer-reviewed veterinary case report

Early Postoperative MRI Evaluation of a Fascia Lata Autograft With and Without Polypropylene Mesh Augmentation After Superior Capsular Reconstruction.

Year:
2023
Authors:
Ben H et al.
Affiliation:
Department of Orthopaedic Surgery · South Korea

Abstract

<h4>Background</h4>Recently, a polypropylene mesh has been introduced and reported to improve clinical outcomes after superior capsular reconstruction (SCR) using a fascia lata autograft (FLA). However, mesh-related events such as a foreign body response may trigger inflammation, which might affect graft healing and remodeling.<h4>Purpose/hypothesis</h4>The aim was to investigate whether the healing and remodeling of an FLA were affected by the use of a mesh by comparing the signal intensity of an FLA-alone group vs an FLA + Mesh group on postoperative magnetic resonance imaging (MRI). The hypothesis was that the use of a mesh would decrease the MRI signal intensity of FLA during the early postoperative phase.<h4>Study design</h4>Cohort study; Level of evidence, 3.<h4>Methods</h4>Patients who had undergone SCR using an FLA with or without a mesh between March 2013 and August 2021 were retrospectively analyzed. Follow-up MRI was performed at 3 months. A total of 78 patients (24 in the FLA group and 54 in the FLA + Mesh group) with intact grafts were included. Graft remodeling was evaluated by analyzing the signal-to-noise quotient (SNQ) at the humeral, mid-substance, and glenoid sites. Theoretically, lower SNQ ratios indicate higher strength and better healing of the graft.<h4>Results</h4>The mean SNQ was 30.603 (range, 11.790-72.710) in the FLA group and 18.367 (range, 4.464-69.500) in the FLA + Mesh group (<i>P</i> < .001). Furthermore, significant differences were found between the 2 groups at the humeral and mid-substance sites (37.863 [range, 5.092-81.187] vs 15.512 [range, 1.814-80.869], <i>P</i> < .001; and 29.168 [range, 6.103-73.900] vs 16.878 [range, 2.454-92.416], <i>P</i> = .003; respectively). However, there was no difference between the 2 groups at the glenoid site (25.346 [range, 7.565-86.353] vs 20.354 [range, 3.732-88.468], <i>P</i> = .057).<h4>Conclusion</h4>At the 3-month follow-up, the FLA + Mesh group showed a lower MRI signal intensity than the FLA group. The healing and remodeling of an FLA may be enhanced when a mesh is used.

Find similar cases for your pet

PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.

Search related cases →

Original publication: https://europepmc.org/article/MED/36786289