Peer-reviewed veterinary case report
Establishment of loop-mediated isothermal amplification (LAMP) for rapid detection of Brucella spp. and application to milk and blood samples.
- Journal:
- Journal of microbiological methods
- Year:
- 2012
- Authors:
- Song, Liuyan et al.
- Affiliation:
- Department of Microbiology · China
Abstract
Brucella spp. are facultative intracellular bacteria that infect humans and animals. In this study, the loop-mediated isothermal amplification (LAMP) was used to detect the Brucella-specific gene omp25. Reaction conditions were optimized as temperature 65°C, reaction time 60 min, Mg(2+) concentration 8.0 mmol/L, polymerase content Bst DNA, 0.5 μL, deoxyribonucleotide concentration 1.6 mmol/L, and inner/outer primer ratio 1:8. The LAMP method was evaluated with 4 Brucella species and 29 non-Brucella bacteria species. Positive reactions were observed on all the 4 Brucella species but not on any non-Brucella species. The limit of detection of the LAMP method was 3.81 CFU Brucella spp. Using the LAMP method, 7 of 110 raw milk samples and 5 of 59 sheep blood samples were detected positive of Brucella spp. Results indicated that LAMP is a fast, specific, sensitive, inexpensive, and suitable method for diagnosis of Brucella spp. infection.