Peer-reviewed veterinary case report
Monitoring of perfusion quality and prediction of donor heart function during ex-vivo machine perfusion by myocardial microcirculation versus surrogate parameters.
- Journal:
- The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation
- Year:
- 2021
- Authors:
- Saemann, Lars et al.
- Affiliation:
- Department of Cardiac Surgery · Germany
Abstract
Currently, lactate (Lac) is used to evaluate machine perfusion (MP) of hearts, donated after circulatory death (DCD). We hypothesize that monitoring of myocardial microcirculation (mLDP) by Laser-Doppler-Perfusion is superior to Lac to evaluate perfusion and predict contractility. In a pig model, DCD-hearts were perfused 4 hours followed by reperfusion and left ventricular contractility measurement. Lac and mLDP were measured every 30 min in successfully (N = 9) and unsuccessfully (N = 7) maintained hearts. Successfully maintained hearts showed decreasing Lac (5.6 to 2.8 mmol/L) and slightly downregulated (92%) mLDP. In unsuccessfully maintained hearts Lac first decreased (5.1 to 3.8 mmol/L) followed by increase and mLDP dropped to 39%. In a single-variable regression only mLDP showed a significant r² for systolic (0.514, p = 0.045) and diastolic (0.501, p = 0.049) parameters. The combination of mLDP and Lac (r = 0.876, p = 0.005) showed best results. mLDP seems to be superior to Lac to show perfusion disorders and predict DCD-heart contractility.
Find similar cases for your pet
PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.
Search related cases →Original publication: https://pubmed.ncbi.nlm.nih.gov/33726982/