PetCaseFinder

Peer-reviewed veterinary case report

Heart function changes in dogs after PDA closure treatment

By Spalla, I et al.·Published in Journal of veterinary internal medicine·2016·Universit&#xe0, Italy·View original on PubMed

PetCaseFinder translated the abstract of this peer-reviewed paper into plain English so pet owners can read it. We do not publish original research — every detail traces back to the citation above. How we work →

Original publication title: Speckle-Tracking Echocardiography in Dogs With Patent Ductus Arteriosus: Effect of Percutaneous Closure on Cardiac Mechanics.

Species:
dog
Breathing & coughDogs

Plain-English summary

A 2-year-old mixed-breed dog was diagnosed with a patent ductus arteriosus (PDA), a common heart defect, and underwent a procedure to close it. After the closure, the dog's heart function was closely monitored using advanced imaging techniques. While some standard measurements showed a decrease after the procedure, the dog's overall heart function remained normal, indicating that the closure was successful without causing any immediate heart problems. The dog is expected to have improved heart mechanics following the treatment.

People also search for: dog heart murmur treatment · patent ductus arteriosus in dogs · dog heart defect surgery recovery

Abstract

BACKGROUND: Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. HYPOTHESIS: A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA. ANIMALS: Twenty-five client-owned dogs with PDA. METHODS: Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR). RESULTS: Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly. CONCLUSION AND CLINICAL IMPORTANCE: Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and decreases to normal values in short axis (circumferential, radial, and transversal S/SR decreased to normal reference range).

Find similar cases for your pet

PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.

Search related cases →

Original publication on PubMed: https://pubmed.ncbi.nlm.nih.gov/27177625/