PetCaseFinder

Peer-reviewed veterinary case report

The Agreement between Feline Pancreatic Lipase Immunoreactivity and DGGR-Lipase Assay in Cats—Preliminary Results

Journal:
Animals
Year:
2021
Authors:
Magdalena Maria Krasztel et al.
Affiliation:
Division of Veterinary Epidemiology and Economics, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159c, 02-776 Warsaw, Poland · CH
Species:
cat

Abstract

The colorimetric catalytic assay based on the use of 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6′-methylresorufin) (DGGR) ester as a substrate for pancreatic lipase activity is commonly used for the diagnosis of pancreatitis in dogs and cats. Even though the assay has generally been shown to yield consistent results with feline pancreatic lipase immunoreactivity (fPLI) assay, the agreement may vary between assays of different manufacturers. In this study, the chance-corrected agreement between a DGGR-lipase assay offered by one of the biggest providers of diagnostic solutions in Poland and fPLI assay was investigated. The study was carried out on 50 cats in which DGGR-lipase activity and fPLI were tested in the same blood sample. The chance-corrected agreement was determined using Gwet’s AC<sub>1</sub> coefficient separately for the fPLI assay’s cut-off values of >3.5 μg/L and >5.3 μg/L. The DGGR-lipase activity significantly positively correlated with fPLI (R<sub>s</sub> = 0.665; CI 95%: 0.451, 0.807, <i>p</i> < 0.001). The chance-corrected agreement between the fPLI assay and DGGR-lipase assay differed considerably depending on the cut-off values of the DGGR-lipase assay. When the cut-off value reported in the literature (>26 U/L) was used, it was poor to fair. It was moderate at the cut-off value recommended by the laboratory (>45 U/L), and good at the cut-off value recommended by the assay’s manufacturer (>60 U/L). The highest agreement was obtained between the fPLI assay at the cut-off value of 3.5 μg/L and the DGGR-lipase assay at the cut-off value of 55 U/L (AC<sub>1</sub> = 0.725; CI 95%: 0.537, 0.914) and between the fPLI assay at the cut-off value of 5.3 μg/L and the DGGR-lipase assay at the cut-off value of 70 U/L (AC<sub>1</sub> = 0.749; CI 95%: 0.577, 0.921). The study confirms that the chance-corrected agreement between the two assays is good. Prospective studies comparing both assays to a diagnostic gold standard are needed to determine which of them is more accurate.

Find similar cases for your pet

PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.

Search related cases →

Original publication: https://doi.org/10.3390/ani11113172