PetCaseFinder

Peer-reviewed veterinary case report

Epidemiology, clinical profile, and outcomes of CSF-diversion catheter-related infections - Prospective cohort study results from a single quaternary neurosurgery referral centre.

Year:
2024
Authors:
Ponnambath DK et al.
Affiliation:
Department of Microbiology · India

Abstract

<h4>Background</h4>Device-associated CNS infections is a major subgroup of healthcare associated CNS infections. Healthcare-associated ventriculitis or meningitis differs considerably from community-acquired meningitis in its epidemiology, pathogenesis, clinical presentation and management.<h4>Objectives</h4>This study aimed to identify the infection rates, the associated risk factors, and outcomes of these life-threatening infections.<h4>Methods</h4>This was a 2-year single center prospective cohort study. Patient's clinical data, laboratory parameters, treatment and their outcomes were collected using data collection tool, and device days were collected from the hospital information system (HIS). Patients were categorised using IDSA criteria as contamination or colonisation or infection. Cox regression model was used for multivariate analysis to estimate hazard risk.<h4>Results</h4>A total of 578 CSF diversion catheters were inserted in 472 patients. The average rate for EVD and LD infection were 11.12 and 11.86 per 1000 device days respectively. The average infection rates for VP and LP shunts were 6% and 5.2% per procedure, respectively. The commonest etiological agent causing CSF diversion catheter-related infection (CDRI) was Klebsiella pneumoniae (n = 14, 40%). The risk factors which were independently associated with increased infection risk by cox regression analysis were drain insertion ≥7 days [HR:11.73, p -0.03], posterior approach of EVD insertion (occipital) [HR:9.53, p - 0.01], pre-OP ASA score>3 [HR:8.28, p - 0.013] presence of EVD/LD leak [HR: 17.24, p < 0.0001], male gender [HR:2.05, p-0.05] and presence of associated peri-operative scalp infections [HR:3.531, p-0.005]. Shift to narrow spectrum surgical prophylactic antibiotic [Coefficient: -1.284, p-0.03] and reduction in CSF sampling frequency [Coefficient: -1.741, p-0.02] were found to be negatively associated with CDRI.<h4>Conclusions</h4>The study demonstrated drain insertion ≥7 days, posterior approach of EVD insertion, presence of EVD/LD leak, male gender and presence of associated peri-operative scalp skin and soft tissue infections were associated with increased risk of infection.

Find similar cases for your pet

PetCaseFinder finds other peer-reviewed reports of pets with the same symptoms, plus a plain-English summary of what was tried across them.

Search related cases →

Original publication: https://europepmc.org/article/MED/38367805